Colorado Journeyman Wireman Exam Preparation

Click "Add to cart" to enroll today!

Original price was: $995.00.Current price is: $495.00.

Confirm your State before the Purchase

For more information, please click the tabs below the Description

Ready to enroll or have questions? Please contact Daniela Gonzalez (303) 916-0020, or click Add to Cart

Colorado Journeyman Wireman Exam Preparation is our specialty since 1972. School enrollment is complete with Home Study Computer Program, Tutoring, and Live Seminars with real questions, answers, code references, and calculations to prepare you for the actual PSI state licensing exam.

Candidates for state licensure must now pass an exam administered by PSI prior to submitting an application for licensure. See the recommended steps listed below:

    1. Study to pass your state exam on the first try with our Home Study Computer Program (Click ADD TO CART above)
    2. Register to take your exam online at www.psiexams.com or call (855) 898-0710
    3. Schedule an appointment to take the examination with PSI
    4. Take and pass the state exam
      • You must bring two valid forms of identification
      • Arrive 30 minutes prior to the scheduled examination appointment.
    5. File a license application with the Board at www.colorado.gov/dora/licensing.

Colorado Division of Professions and Occupations Online Services (DORA):

Electrical web address: https://dpo.colorado.gov/Electrical
State Electrical Board, 1560 Broadway, Suite 1350, Denver, CO 80202. (303) 894-7800

Why Wait? Call Daniela Today! (303) 916-0020

 

 

Below are a few questions from your upcoming PSI state exam:

  1. What would be the calculated the voltage drop on the #6 AWG copper conductors that serve a 15 HP, 480 V three-phase motor? (Assume the voltage source and the load are 150 feet apart installed in rigid metal conduit.)
    • Correct Answer: NEC – Table 430.250, Chapter 9 Table 8 (Conductor Properties), and Voltage Drop formula. See calculation steps below.
      1. Per Table 430.450 the FLC for the 15 HP 480 V motor is 21 amperes.
      2. Per Chapter 9 Table 8 the #6 AWG Circular mils is 26240.
      3. Use the Voltage Drop Formula, Vd = (1.732 x K x Length x Ampacity) / kcmil, Vd = (1.732 x 12.9 x 150 feet x 21 amps) / 26240 = 2.68 Volts.
  2. What is the minimum required feeder tap conductor size for a circuit protected by an 800 ampere OCP device, where the length of the tap conductors is 20 feet, using copper THWN wire?
    • Correct Answer: NEC – 240.21(B)(2)(1) Therefore, calculate; 800 amperes / 3 = 266 amperes, then use Table 310.15(B)(16) 75-degree C (THWN) column to size the feeder tap as 300 kcmil.
  3. The ampere rating of a feeder that supplies a continuous lighting load and a motor load shall be how many amperes when the lighting load is equivalent to 39 amperes and the motor load is equivalent to 24 amperes?
    • Correct Answer: 430.22, and 600.5(B) Therefore, calculate the total load by: 39 amperes + 24 amperes = 63 amperes, then multiply by 125%. 63 amperes x 1.25 = 78.75 amperes.
  • NEC 2023 (NFPA National Electrical Code)

Testimonials